| | |  Kewtech provide a range of testers and diagnostic instruments of proven reliability and accuracy. Most of the products in the Kewtech range are manufactured by Japan's Kyoritsu Corporation, a long established company that has gained a worldwide reputation for producing robust, easy-to-use instruments that will give you years of reliable service at a price you can afford. We consider the service and support function critical to the satisfaction of our customers and our long-term success. The Kewtech technical team is one of the industry's most experienced and best trained and capable of repairing and re-calibrating your instrument in the shortest possible time both within and outside of warranty periods.
Kewtech KEW2003A DIGITAL HIGH CURRENT AC/DC CLAMP METER
Data
[Read More]
[Read Less]
- Measures current up to 2000A AC/DC
- Measures voltage up to 750V AC & 1000V DC
- Output voltage
- Max hold memory function
- Resistance
- Continuity buzzer
- Large 55mm tear drop jaw
- Complies to IEC61010-1 CAT. III 600V, CAT. II 1000V and CAT. IV 600V
|
| Features
|
|
- 400A/2000A (0 ~ 1000A)
±1.5%rdg + 2dgt (50/60Hz) ±3%rdg + 4dgt (40Hz ~ 500Hz) ±5%rdg + 4dgt (500Hz ~ 1kHz) 2000A (1001 ~ 2000A) ±3%rdg + 2dgt ((50/60Hz)
|
|
- 400/750V
±1.5%rdg + 2dgt (50/60Hz) ±1.5%rdg + 4dgt) (40Hz ~ 1kHz)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- IEC61010-1 CAT III 600V 1000V
IEC61010-2-031 IEC61010-2-032
|
|
|
|
|
|
|
|
- 250(L) x 105(W) x 49(D)mm
|
|
|
|
- 8004/8008 Multi-Tran (AC only), 7014 Output Cord
|

Kewtech KEW2016R 2000A TRUE RMS CLAMP METER Data[Read More]
[Read Less]
- Can measure large AC current up to 2000A
- 55mm-diameter large tear drop shaped jaws
- Output terminal for connection to recorders
- Peak memory function
- Designed to international safety standard IEC61010-1 CAT.III 600V
|
| Features |
|
|
- (0~400A)
±1.5%rdg±3dgt (45~65Hz) ±2.5%rdg±3dgt (40Hz~1kHz)
- (0~1500A)
±2%rdg±5dgt (45~65Hz) ±3%rdg±5dgt (40Hz~1kHz) (1501~2000A) ±4%rdg (50/60Hz)
|
|
|
|
|
|
- AC400A (DC400mV)
AC2000A (DC200mV)
|
|
|
|
- 3 or less: accuracy+1% (45~65Hz),
less than AC3000A/1200V Peak
|
|
- IEC61010-1 (JIS C 1010-1) CAT. III 600V
CAT. III 1000V IEC61010-2-031 (JIS C 1010-2-31) IEC61010-2-032 (JIS C 1010-2-32), IEC61326-1
|
|
|
|
- 247(L) x 105(W) x 49(D) mm
|
|
|

Kewtech KEW2040 AC CAT. IV DIGITAL CLAMP METER Data[Read More]
[Read Less]
- Measures both very low and high power circuits
- Measures current up to 6000A AC/DC
- Measures voltage up to 600V AC/DC
- Min/Max memory for extended testing
- Continuity buzzer
- Frequency
- LED non-contact voltage indicator
- 33mm jaw size
- Display: 6039 counts with bar graph
- Lowest resolution 0.1A
- Complies to IEC61010-1 CAT. IV 600V
|
| Features |
|
- 0~600.0A
±1.5%rdg±5dgt (50/60Hz) ±3.5%rdg±8dgt (40~400Hz)
|
|
- 6/60/600V
Auto Ranging ±1.3%rdg±4dgt (50/60Hz) ±3.0%rdg±5dgt (40~400Hz)
|
|
- 600m/6/60/600V
Auto Ranging ±1.0%rdg±3dgt
|
|
- 600/6k/60k/600k/6M/60MΩ (Auto Ranging)
±1%rdg±5dgt (600~6M) / ±5%rdg±8dgt (60M)
|
|
|
|
- 10/100/1k/10kHz (Auto Ranging) / 0.1~99.9%
|
|
|
|
|
|
|
|
- IEC 61010-1 CAT.IV 600V,
IEC61010-031, IEC61010-2-032, IEC61326
|
|
|
|
|
|
|

Kewtech KEW2300R TRUE RMS DIGITAL AC/DC FORK CURRENT TESTER Data[Read More]
[Read Less]
- True RMS for highly accurate readings
- Measures current 100A AC/DC
- Perfect for use in small and confined spaces
- Non contact voltage detection with audible tone
- One touch range adjustment for easy use
- Data hold memory function
- Auto power off
- Complies to IEC61010-1 CAT. III
|
| Features |
|
|
|
|
- AC A 0 to 100.0A
DC A 0 to ±100.0A
|
- ±2.0% edg±5dgt (50/60Hz)
±2.0%edg±5dgt
|
|
|
|
- Detect AC voltage
without contacting with wire socket wire
|
- During voltage detection,
"Hi" flashes and a buzzer sounds intermittently
|
|
- TRMS with rolling average
|
|
- 161.3(L) x 40.2(W) x 30.3(D) mm
|
|
|
|
|
|
|
|
- IEC 61010-1 CAT .II 300V Pollution Degree 2
|
|
|

Kewtech KEW2046R TRUE RMS AC/DC CAT IV DIGITAL CLAMP METER Data[Read More]
[Read Less]
- True RMS for highly accurate readings
- Measures both very low and high power circuits
- Measures current up to 600A AC/DC
- Measures voltage up to 600V AC/DC
- Min/Max memory for extended testing
- Continuity buzzer
- Frequency
- Capacitance
- Temperature measurement (with KEW8216 temperature probe)
- Non-contact voltage indicator
- 33mm jaw size
- LED Non contact voltage detection
- Display: 6039 counts with bar graph
- Lowest resolution 0.1A
- Complies to IEC61010-1 CAT. IV 600V
|
| Features |
|
- 0~600.0A
±2.0%rdg±5dgt (50/60Hz) ±3.5%rdg±5dgt (40~500Hz)
|
|
|
|
- 6/60/600V
Auto Ranging ±1.5%rdg±4dgt (50/60Hz) ±3.5%rdg±5dgt (40~400Hz)
|
|
- 600m/6/60/600V
Auto Ranging ±1.0%rdg±3dgt
|
|
- 600/6k/60k/600k/6M/60MΩ (Auto Ranging)
±1%rdg±5dgt (600~6MΩ) / ±5%rdg±8dgt (60MΩ)
|
|
|
|
- 10/100/1k/10kHz (Auto Ranging) / 0.1~99.9%
|
|
- -50ºC ~ +300ºC (With the use of Temperature probe 8216)
|
|
|
|
|
|
|
|
- IEC 61010-1 CAT.IV 600V,
IEC61010-031, IEC61010-2-032, IEC61326
|
|
|
|
|
|
|

Kewtech KEW2055 Clamp Meter Data[Read More]
[Read Less]
- Measures both very low and high power circuits
- Measures current up to 1000A AC/DC
- Measures voltage up to 600V AC/DC
- Min/Max memory for extended testing
- Continuity buzzer
- Frequency
- Non-contact voltage indicator
- 40mm jaw size
- LED Non contact voltage detection
- Display: 6039 counts with bar graph
- Lowest resolution 0.1A
- Complies to IEC61010-1 CAT. IV 600V
|
| Features |
|
- 0~600.0 / 1000A
±1.5%rdg±5dgt (50/60Hz) ±3.0%rdg±5dgt (40~400Hz)
|
|
- 0~600.0 / 1000A
±1.5%rdg±5dgt
|
|
- 6 / 60 / 600V
Auto Ranging ±1.3%rdg±4dgt (50/60Hz) ±3.0%rdg±5dgt (40~400Hz)
|
|
- 600m /6 / 60 / 600V
Auto Ranging ±1.0%rdg±3dgt
|
|
- 600 / 6k / 60k / 600k / 6MΩ / 60MΩ (Auto Ranging)
±1%rdg±5dgt (600~6MΩ) / ±5%rdg±8dgt (60MΩ)
|
|
|
|
- 10/100/1k/10kHz (Auto Ranging) / 0.1~99.9%
|
|
|
|
|
|
|
|
- IEC 61010-1 CAT.IV 600V,
IEC61010-031, IEC61010-2-032, IEC61326
|
|
|
|
|
|
|
|
|

Kewtech Kew2056R TRUE RMS AC/DC CAT IV DIGITAL CLAMP METER Data[Read More]
[Read Less]
- True RMS for highly accurate readings
- Measures both very low and high power circuits
- Measures current up to 1000A AC/DC
- Measures voltage up to 600V AC/DC
- Min/Max memory for extended testing
- Continuity buzzer
- Frequency
- Capacitance
- Temperature measurement (with KEW8216 temperature probe)
- Non-contact voltage indicator
- 40mm jaw size
- LED Non contact voltage detection
- Display: 6039 counts with bar graph
- Complies to IEC61010-1 CAT. IV 600V
|
| Features |
|
- 0 ~ 1000.0A
±2.0%rdg±5dgt (50/60Hz) ±3.5%rdg±5dgt (40~500Hz)
|
|
|
|
- 6/60/600V
Auto Ranging ±1.5%rdg±4dgt (50/60Hz) ±3.5%rdg±5dgt (40~400Hz)
|
|
- 600m/6/60/600V
Auto Ranging ±1.0%rdg±3dgt
|
|
- 600/6k/60k/6MΩ (Auto Ranging)
±1%rdg±5dgt (600~6MΩ) / ±5%rdg±8dgt (60MΩ)
|
|
|
|
- 10/100/1k/10kHz (Auto Ranging) / 0.1~99.9%
|
|
- -50°C ~ +300% (With the use of Temperature probe 8216)
|
|
|
|
|
|
|
|
- IEC61010-1 CAT.IV 600V
IEC61010-031 IEC61010-2-032 IEC61326
|
|
|
|
|
|
|

Kewtech Kt200 Clamp Meter Data[Read More]
[Read Less]
- Measures Current up to 400A AC
- Measures Voltage up to 600V AC
- Resistance
- Continuity buzzer
- 33mm jaw
- Sleep feature
- Data hold
- Display: 4000 counts
- Complies to IEC61010-1 (CAT. III) Ul3111 & VDE0411 300V
|
| Features |
|
|
|
|
|
|
|
|
|
|
- AC Voltage (V) AUTO-Ranging (50/60hz)
|
|
|
|
|
|
|
| |
|
- DC VOLTAge (V) AUTO-Ranging
|
| |
|
| |
|
|
|
|
- Resistance (CONTINUITY) AUTO-Ranging
(Buzzer Beeps Below 50±35Ω)
|
|
| |
|
|
|
|
|
|

Kewtech Kt203 Clamp Meter Data[Read More]
[Read Less]
- Measures Current up to 400A AC/DC
- Measures Voltage up to 600V AC/DC
- Resistance
- Continuity buzzer
- 33mm jaw Sleep feature
- Data hold memory function
- Display: 4000 counts
- Complies to IEC61010-1 (CAT. III) Ul3111 & VDE0411 300V
|
| Features |
| AC CURRENT (A) AUTO-RANGING (50/60HZ) |
|
|
|
|
|
|
|
|
|
| | |
|
| DC CURRENT (A) AUTO-RANGING |
|
|
|
|
|
|
|
|
|
|
|
|
| AC VOLTAGE (V) AUTO-RANGING (50/60HZ) |
|
|
|
|
|
|
|
|
| DC VOLTAGE (V) AUTO-RANGING |
|
|
|
|
|
|
|
|
|
| RESISTANCE (Ω/CONTINUITY) AUTO-RANGING (BUZZER BEEPS BELOW 50±35Ω) |
|
|
|
|
|
|
|
|
|
|
|

Kewtech KEW2432 DIGITAL EARTH LEAKAGE CLAMP METER HIGH SENSITIVITY Data[Read More]
[Read Less]
- Measures 4mA/40mA/100A AC current
- Resolution to 0.001mA
- Frequency selector switch to eliminate harmonics
- 40mm jaw
- Peak hold function
- Sleep feature to save batteries
- Peak memory function
- Ideal for fault finding on installations with nuisance tripping and leakage faults
- Complies to IEC61010-1 CAT. III 300V
|
| Features |
|
- 4 / 40mA / 100A
±1% rdg ± 5dgt [4 / 40mA] ±1% rdg ± 5dgt [0 ~ 80A] ±5% rdg (80.1 ~ 100A)
|
|
- 4 / 40mA / 100A
±1% rdg ± 5dgt [50/60Hz] ±2.5% rdg ± 10dgt [40Hz~1kHz] (0~80A) ±1% rdg ± 5dgt [50/60Hz] ±2.5% rdg ± 10dgt [40Hz~1kHz] (0~80A) ±5% rdg [50/60Hz] ±2.5%rdg [40Hz~1kHz] (80.1~100A)
|
|
- 20Hz~1kHz (40Hz~1kHz: 100A)
|
|
- 600V AC/DC (between line/neutral)
|
|
- 300V AC/DC (against earth)
|
|
|
|
- IEC61010-1 CATIII 300V Pollution Degree 2
IEC61010-2-032
|
- Effect of External
Stray Magnetic Field
|
- 2mA AC approx in proximity to a 15mm-dia conductor
carrying 100A AC
|
|
|
|
|
|
- Two R03 or equivalent (DC1.5V) batteries
|
|
|
|
|

Kewtech KEW2434 DIGITAL EARTH LEAKAGE CLAMP METER Data[Read More]
[Read Less]
- Measures 400mA/4A/100A AC current
- Resolution to 0.1mA
- Frequency selector switch to eliminate harmonics
- 28mm jaw
- Sleep feature to save batteries
- Reading Type: Averaging
- Ideal for fault finding on installations with nuisance tripping and leakage faults
- Complies to IEC61010-1 CAT. III 300V
|
| Features |
|
- 400mA / 4 / 100A ±2% rdg ± 4dgt
|
|
- 400mA / 4 / 100A ±2% rdg ± 4dgt [50/60Hz]
±3% rdg ± 5dgt [40~400Hz]
|
|
|
|
- IEC61010-1 CAT.III 300V
IEC61010-2-032
|
- Effect of External
Stray Magnetic Field Ø15mm 100A
|
|
|
|
|
|
- Effect of External
Stray Magnetic Field
|
- 2mA AC approx in proximity to a 15mm-dia conductor
carrying 100A AC
|
|
|
|
|
|
|

Kewtech KEW8008 Clamp Adaptor Data[Read More]
[Read Less]
- Enables reading of up to 3000A AC
- Large 100mm jaw
- Complies to IEC61010-1 CAT. III 300V pollution degree 2
|
| Features |
|
|
|
|
|
- 1000-1500A (10 minutes max)
|
|
|
|
- IEC 61010-1 CAT III 300V Pollution
Degree 2
|
|
- 317(L) x 150W x 30(D)mm
45(L) x 30(W) x 10(D)mm Output coil
|
|
|
- For use with the
following models
|
- 2002PA, 2003R, 2003A (AC only), 2004(AC only), 2006,
2007A(AC only), 2009A (AC only), 2608A, 2805, 2017, 2027, 2037(AC only), 2412, 2417, 8113(AC only), 2031, 2033(AC only), 2431, 2332, 2433, 2433R, 2434
|

Kewtech KEW8112 Clamp Adaptor Data[Read More]
[Read Less]
- Measures current from 0.1mA to 120A
- Small 8mm jaw
- Complies to IEC61010-1 CAT. II 100V pollution degree 2
|
| Features |
|
|
|
|
|
|
|
|
- ±1.5%rdg ±0.2mA
±3%rdg ±0.4mA
|
|
|
|
|
|
|
|
- AC 0~20A
AC 20-60A AC 60~120A
|
|
- ±1%rdg ±0.01A
±2.5%rdg ±2.5%rdg
|
- 40Hz~1kHz
50Hz~10kHz 100Hz~10kHz
|
|
|
|
|
|
- IEC61010-1 CAT.II 100V Pollution Degree 2
|
|
|
|
|
|
|

|