Fluke 8845A & Fluke 8846A Bench Multimeters 6½ Digits Data[Read More]
[Read Less] C/w Free Calibration Certificate Traceable to National Standards

The Fluke 8845A and 8846A 6.5 digit precision multimeters have the precision and versatility to handle your most demanding measurements, on the bench or in a system. These meters are both high performance and feature rich, yet also remarkably easy to use.
These digital multimeters perform the functions you would expect to see in a multifunction DMM, including measuring volts, ohms, and amps. Basic V dc accuracy of up to 0.0024 %, 10 A current range, and a wide ohms range give you an unbeatable combination of measurement capability.
You can also use the 8845A and 8846A to measure frequency and period. In addition, the Fluke 8846A measures temperature and capacitance. The functions of a counter, capacitance meter, and thermometer are built in for unparalleled versatility. Extend the meters' utility even more with their graphical display modes, including TrendplotTM paperless recorder mode, statistics and histograms features you won't find on other multimeters.
Of course, these meters are also durable and dependable, features you expect from any Fluke meter. This unique combination of features and performance makes the 8845A and Fluke 8846A an unbeatable value for a wide variety of applications, including manufacturing test, research and development, and service.
| Technical Specifications
|
|
|
|
|
|
- Ranges:
Max. Resolution:
Accuracy:
|
- 100 mV to 1000 V
100 nV
8845A: 0.0035 + 0.0005 (% measurement + % of range)
8846A: 0.0024 + 0.0005 (% measurement + % of range)
|
|
- Ranges:
Max. Resolution:
Accuracy:
Frequency:
|
- 8845A: 100 mV to 750 V
8846A: 100 mV to 1000 V
100 nV
8845A: 0.06 + 0.03 (% measurement + % of range)
8846A: 0.06 + 0.03 (% measurement + % of range)
3 Hz to 300 KHz
|
|
- 2x4 Wire:
Ranges:
Max. Resolution:
Accuracy:
|
- Yes
8845A: 100 Ω to 100 MΩ
8846A: 10 Ω to 1 GΩ
8845A: 100 µΩ
8846A: 10 µΩ
8845A: 0.010 + 0.001 (% measurement + % of range)
8846A: 0.010 + 0.001 (% measurement + % of range)
|
|
- Ranges:
Max. Resolution:
Accuracy:
|
- 100 µA to 10 A
100 pA
0.050 + 0.005 (% measurement + % of range)
|
|
- Ranges:
Max. Resolution:
Accuracy
Frequency:
|
- 8845A: 10 mA to 10 A
8846A: 100 mA to 10 A
8845A: 10 nA
8846A: 100 pA
0.10 + 0.04 (% measurement + % of range)
3 Hz to 10 kHz
|
|
- Ranges:
Max. Resolution:
Accuracy:
|
- 8845A: 3 Hz to 300 kHz
8846A: 3 Hz to 1 MHz
1 µHz
0.01 %
|
|
|
|
- Ranges:
Max. Resolution:
Accuracy:
|
- 8846A: 1 nF to 0.1 F
8846A: 1 pf
8846A: 1 %
|
|
- Type:
Ranges:
Max. Resolution:
Accuracy:
|
- 8846A: Platinum RTD
8846A: -200 °C to +600 °
8846A: 0.01 °
8846A: 0.06 °
|
|
|
- NULL, Min/Max/Average, Std Dev
Yes
|
|
- Statistics/Histogram:
Trendplot:
Limit Test:
|
|
|
- USB Memory:
Real Time Clock:
Interfaces:
Programming
Languages/Modes:
|
- 8846A: USB memory drive port
8846A: Yes
RS 232, IEE-488.2, Ethernet, USB (with optional adaptor)
8846A: SCPI (IEEE-488.2), Agilent 34401A, Fluke 45
|
| General Specifications |
|
|
|
- 88 mm x 217 mm x 297 mm (3.46 in x 8.56 in x 11.7 in)
|
|
- Designed to comply with IEC 61010-1:2000-1, UL 61010-1A1, CAN/CSA-C22.2 No. 61010.1, CAT I 1000V/CAT II 600V
|
|
|

|