Instruments
Fluke 718Ex 1G I.S. Pressure Calibrator (68.9 mbar)
Fluke 718Ex 30G I.S. Pressure Calibrator (2 bar)
Fluke 718Ex 100G I.S. Pressure Calibrator (7 bar)
Fluke 718Ex 300G I.S. Pressure Calibrator (20 bar)
Modules
Fluke 700P01Ex Differential Pressure Module (25 mbar)
Fluke 700P24Ex Differential Pressure Module Wet (1001 mbar)
Fluke 700P05Ex Gauge Pressure Module (2 bar)
Fluke 700P06Ex Gauge Pressure Module (7 bar)
Fluke 700P27Ex Gauge Pressure Module (20 bar)
Fluke 700P09Ex Gauge Pressure Module (100 bar)
Fluke 700P29Ex Gauge Pressure Module (200 bar)
Fluke 700PA4Ex Absolute Pressure Module (1000 mbar)
|
|
| Measurement Accuracy |
|
- Fluke 718Ex 30G
Range:
Resolution: Accuracy: Functions:
|
-830 mbar to 2 bar (internal sensor) Over pressure: 3x FS 0.0001 bar 0.05% FS Zero, Min, Max, Hold, Damp Note: for use with non-corrosive gasses
|
|
- Fluke 718Ex 100G
Range:
Resolution: Accuracy: Functions:
|
-830 mbar to 7 bar (internal sensor) Over pressure: 2x FS 0.001 bar 0.05% FS Zero, Min, Max, Hold, Damp Note: for use with non-corrosive gasses
|
|
- Fluke 718Ex 300G
Range:
Resolution: Accuracy: Functions:
|
-830 mbar to 20 bar (internal sensor) Over pressure: 375 psi, 25 bar 0.0001 bar 0.05% FS Zero, Min, Max, Hold, Damp Note: for use with non-corrosive gasses
|
|
- Fluke 718Ex series
Range:
Resolution: Accuracy: Functions:
|
via pressure module connector 29 pressure modules, 2.5 mbar to 700 bar Over pressure per pressure module specs Per pressure module specs To 0.025% of full span, per pressure module specs Zero, Min, Max, Hold, Damp Note: media compatibility per pressure module specs
|
|
- Source Pressure, built in pump
Range: Note:
|
-820 mbar to full scale Supported Pressure Units PSI, in. H2O (4 °C), in. H2O (20 °C), kPa, cm H2O (4 °C),
cm H2O (20 °C), bar, mbar, kg/cm², mmHg, in Hg
|
| Environmental Specifications |
|
|
|
|
- Humidity (Without Condensation)
|
- 95% (10ºC to 30ºC)
75% (30ºC to 40ºC) 45% (40ºC to 50ºC) 35% (50ºC to 55ºC)
|
|
|
| Safety Specifications |
|
- ATEX II 1G Ex ia IIC T4 compliant
CSA Certification I.S. Class I, Div 1 Groups A-D , T4
|
| Mechanical & General Specifications |
|
- 216 mm L x 94 mm W x 66 mm H (with holster)
|
|
- Approx. 992 g (with holster)
|
|
- Three years, one year for pump
|
|
|
|
|
|
- One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V
Battery life: 4 to 20 hours, depending on functions used
|
|